TSP-EP10 SERIES
POE Transformer
  • Flyback transformers for PoE applications.
  • Designed to operate in continuous mode at 250 kHz with an input of 36 ~ 72 VDC.
  • One minute isolation (hipot): 1500 Vrms, from primary and aux to secondary,500 Vrms
    between all other windings.
  • Operating temperature range: -40°C~+125°C, self-temperature rise included.
Resource Download

Product specifications

Pri.:Sec.:Aux
Pri.:Sec.:Aux
TSP-EP10S01 155 139.5 4 414 36 822 1 : 0.190 : 0.667 0.65 36 ~ 72 3.3 , 2.12 7 1500 Flyback 802.3af Class 0-3
TSP-EP10S02 155 139.5 3.6 414 60 822 1 : 0.262 : 0.667 0.65 36 ~ 72 5.0 , 1.4 7 1500 Flyback 802.3af Class 0-3
TSP-EP10S03 155 139.5 3.25 414 34.3 822 1 : 0.667 : 0.667 0.65 36 ~ 72 12 , 0.6 7 1500 Flyback 802.3af Class 0-3

Notes:

1. All electrical specifications are referenced to 25°C ± 5°C ambient.
2. The inductance is for the primary, measured at 250 kHz, 0.1 Vrms, 0 ADC.
3. The peak primary current drawn at minimum input voltage.
4. The leakage inductance is for the primary with all other windings shorted.
5. Turns ratio is with the secondary windings connected in parallel.
6. Output is with the secondary windings connected in parallel. Output of the bais winding is 12 V, 20 mA.

Recommended products